What was found
INSPECTION TYPE: C, PERFORM A GVI OF CAPT & F/O CONTROL YOKES & ATTACHED LINKAGE, PAYING ATTENTION TO CORROSION, BINDING OR LOOSENESS OF BEARINGS. ROTATE EACH CONTROL WHEEL FULL TRAVEL LEFT & RIGHT CHECKING FOR ANY STIFFENESS, BINDING OR RATCHETING OF MOVEMENT. OPERATE AILERON TRIM FULL TRAVEL IN EACH DIRECTION CHECKING FOR BINDING & FRICTION. GVI CARRIED OUT IAW UPS GMM 4-3-1. FOUND SATISFACTORY. BACKLASH ON CAPT'S CONTROL WHEEL ADJUSTED IAW OHM27-16-01 STEP 12P502 & RATCHETING FOUND REMOVED. AILERON TRIM & CENTERING SPRINGS REPLACED & ADJUSTED TO MAX. LIMIT PER OHM 27-11-01. ALL PULLEYS & LINKAGES LUBED IAW MM. TRIM SYS CHECKED & NO LAGGING FOUND. CONTROL COLUMNS RECONN.