What was found
INSPECTION TYPE:C CORROSION ON LOWER FLANGE OF STR 18A AT BS 850 RT VAPOR SEAL REMOVED FOR ACCESS IAW MM 51-30-00. CORROSION REMOVED ON LOWER FLANGE OF STR 18A IAW SRM 51-10-02. HFEC OF ABOVE AREA CARRIED OUT IAW B727-NDTM 51-00-00 PT6 FIG 4. ALL CORROSION REMOVED. FLAP PEENING CARRIED OUT IAW SOPM 20-10-03. REPAIR STRAPS FABRICATED IAW DRWG 6 5C27166 AND EO 2004-083-008 (727-53-20165) CAD PLATING CARRIED OUT.