What was found
INSPECTION TYPE:C DURING REPAIR ASSESSMENT PROGRAM ACCOMPLISH, ITEM N672-41-08 AT BS 447-463 STR 42R-44R 2 LAYERS REPAIR DOUBLER FOUND SINCE THE OUTER DOUBLER IS ONLY 0.040 INCH THK WHICH WILL CREATE KNIFE-EDGE CONDITION, RE-DO THE REPAIR REQUIRE. EXISTING DOUBLER REMOVED & DISCARDED AS PER SRM 53-30-03 FIG 1. HFEC INSPECTED AT THE REPAIR AREA FASTENER HOLES, NO CRACK REVEALED. NEW EXTENDED DOUBLER REPAIRED AS PER SRM 53-30-03 FIG 1. SUBSEQUENCE INSPECTION REQUIRE AS PER SRM 53-30-03 FIG 1 TABLE IV (REPEAT INSPECTION PER EO B747-5330-13494H).