What was found
INSPECTION TYPE:C EMP- RT AFT FUSELAGE UPPER EXTERNAL SKIN SURFACE FOUND CHAFING MARK AT STA 2280 TO STA 2360 , STR 2R TO 3R VERTICAL STABILIZER SEAL INTERFACE AREA (AS MARK). BS 2280-2360 STR 2R-3R AREA SKIN SMOOTHED OUT & REPROTECTED AS PER SRM 51-10-01 & 51-10-02 WITHIN EO 5330-18431 APP-A ITEM 8 LIMITS. HFEC INSPECTED, NO CRACK FOUND EXCEPT BS 2329-2360 STR 2R-4R. BS 2280-2310 STR 2R-3R SKIN REPAIRED AS PER SRM 53-30-03 FIG 1. (UPS MPI ASSIGNED FOR REPEAT INSPECTION).