What was found
INSPECTION TYPE:C EO747-5330-13494-H REPAIR ASSESSMENT PROGRAM DURING MARK ACCOMPLISH, TAR 106855 REPAIR AGAIN AT BS 1905-1913 STR 42R AFT CARGO DOOR AFT EDGE AREA WHICH MAY INTERFERE WITH THE EXISTING REPAIR AT ITEM N672-46-26, BS 1915-1920 STR 41-42R. EXPENDED DOUBLER REPAIRED AS PER SRM 52-30-06 FIG 1 AT AFT CARGO DOOR AFT LWR CORNER BS 1905-1920 STR 41R-42R AREA. REPEAT INSPECTION REQUIRED AS PER SRM 52-30-06 FIG 1 SHT 12 TABLE II. REPEAT INSPECTION IS REQUIRED PER EO B747-5330-13494-H.