What was found
INSPECTION TYPE: C, M/D - LEFT NR 4 DOOR FWD CUTOUT FWD FRAME APPROX S16L AREA, FRAME I/B FWD FACE FOUND CRACK AS MARKED. FWD FRAME CRACKED PORTION TRIMMED OFF, REPAIRED AS PER HX RS 53-62-35110. SURROUNDING STRUCTURE IS CORROSION AND DAMAGE FREE AFTER INSPECTED. NDT INSPECTED THE TRIMMED AREA, NO CRACK FOUND UPS ENGINEERING FILE 747-53-20171.