What was found
INSPECTION TYPE: C, M/D- BS 2160 STR 2L, FRAME ATT. TIE CLIP FOUND CORROSION. CORROSION REMOVED IAW SRM 51-10-01, CORROSION BLEND OUT 0.040 INCH X 1 INCH X 2 INCHES, EXCEED SRM 53-10-01 FIG 1 LIMITS. TIE CLIP REPLACED REF. SRM 51-10-01 P.8 , AND CIC APPLIED IAW EO NR M-5100-2780-E.