What was found
INSPECTION TYPE:C CTR TANK FRONT SPAR UPPER CHORD SHEAR TIE FOUND CRACKED AT LBL 75. SHEAR TIE REPLACED IAW SRM 51-10-01 P8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C CTR TANK FRONT SPAR UPPER CHORD SHEAR TIE FOUND CRACKED AT LBL 75. SHEAR TIE REPLACED IAW SRM 51-10-01 P8.