What was found
INSPECTION TYPE: SPV, FLOORBEAM 65B38095 STA 1900, LBL 98.58, SEAT TRACK ATTACH HOLES FOUND OVERSIZED FWD HOLE 0.350, AFT HOLE 0.390. REMOVED AFT ATTACH ANGLE, REAMED BEAM HOLES FWD 0.389, AFT 0.432 PER EO. FAB & INSTALLED 2EA FREEZE PLUGS PER SKETCH & SRM 51-10-08. FWD ATTACH FITTING 69B04576-7 GOUGED BEYOND LIMITS. FAB & INSTALLED -7 PER DWG AND SK AFT FTG 69B04576-5. FAB & INSTALLED PER DWG & SK, C/W SAA SK675-619.