What was found
INSPECTION TYPE: C, U/D BS 330, BET STR 13-14R, APPROX RBL 70-75 FLOORBEAM WEB FOUND CRACK. U/D FLOORBEAM WEB REPAIRED AS PER SRM 53-10-07 FIG 11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, U/D BS 330, BET STR 13-14R, APPROX RBL 70-75 FLOORBEAM WEB FOUND CRACK. U/D FLOORBEAM WEB REPAIRED AS PER SRM 53-10-07 FIG 11.