Service difficulty report · Floorbeam · Boeing 747200

Difficulty date
October 28, 2004
Submitted
November 10, 2004
Operation
Air carrier
Aircraft
N521UP
Make and model
Boeing 747200
Aircraft serial
21944
Aircraft time
73,613 hours, 17,591 cycles
Part
Floorbeam
Condition
Cracked
Location
Fuselage
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

INSPECTION TYPE:C, LT BS 340 WL 280-320 UPPER DECK FLOORBEAM ONE EA FASTENER HOLE CRACK REVEALED AT FLOORBEAM UPPER CHORD AND STRAP LAYER. FLOORBEAM REPAIRED AS PER SRM 53-10-07 FIG 23 PLUS SB 747-53A2459 REV 1 PART 3 MODIFICATION.