What was found
INSPECTION TYPE:C, LT BS 340 WL 280-320 UPPER DECK FLOORBEAM ONE EA FASTENER HOLE CRACK REVEALED AT FLOORBEAM UPPER CHORD AND STRAP LAYER. FLOORBEAM REPAIRED AS PER SRM 53-10-07 FIG 23 PLUS SB 747-53A2459 REV 1 PART 3 MODIFICATION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, LT BS 340 WL 280-320 UPPER DECK FLOORBEAM ONE EA FASTENER HOLE CRACK REVEALED AT FLOORBEAM UPPER CHORD AND STRAP LAYER. FLOORBEAM REPAIRED AS PER SRM 53-10-07 FIG 23 PLUS SB 747-53A2459 REV 1 PART 3 MODIFICATION.