What was found
INSPECTION TYPE: ETOP ATB, ABOUT 30 MIN OUT OF ANC, LT ENG OIL QTY DROPPING. A/C RETURNED TO ANC. NO EMERGENCY DECLARED. INSPECTED ENGINE OIL SYSTEM, DRAINED OIL TANK & RESERVICED WITH 23 QTS PER FIM 79-11-00 FIG 107. RAN ENG, NO DEFECTS NOTED. OK FOR SERVICE.