What was found
INSPECTION TYPE: C1, FWD PIT CROSS-SLIDE DOOR T-BOLT FITTINGS GOUGED 6 EACH. BLENDED OUT LATCH FITTING IAW DC8 SRM 51-1-8 OUT OF LIMITS IAW DAC DWG 3754051. RECEIVED, LOCATED, & DRILLED 6 EACH LATCH FITTINGS IAW DC8 SRM 51-1-24 AND 51-3-2. ALODINED & PRIMED IAW DC8 SRM 51-1-8. INSTALLED 6 EACH LATCH FITTINGS IAW DC8 SRM 51-1-21, 51-1-20D AND 51-3-0.