What was found
INSPECTION TYPE: C1, REMOVED BATHTUB FITTING AT STA 879 AND FOUND THE SKIN UNDER FITTING CORRODED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW DC8 SRM 53-2-0 AND 53-4-1. MATERIAL ID FOR FILLER IAW REO G09662, FABBED FILLER IAW REO G09 662. ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED FILLER IAW REO G09662.