What was found
INSPECTION TYPE: C3, INTERCOSTAL SUPPORT CLIP IS CRACKED ON FWD SIDE OF AFT PRESSURE BULKHEAD STATION 1766 AT LONG 4L. REMOVED, FABRICATED AND REPLACED SUPPORT CLIP IAW DWG 5773844 AND SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C3, INTERCOSTAL SUPPORT CLIP IS CRACKED ON FWD SIDE OF AFT PRESSURE BULKHEAD STATION 1766 AT LONG 4L. REMOVED, FABRICATED AND REPLACED SUPPORT CLIP IAW DWG 5773844 AND SRM 51-1-20D.