What was found
INSPECTION TYPE: C3, STATION 1240 LONG 33R INTERCOSTAL TO FRAME FITTING IS CRACKED. REMOVED, FABRICATED AND REPLACED FITTING IAW DWG 4758514 AND SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C3, STATION 1240 LONG 33R INTERCOSTAL TO FRAME FITTING IS CRACKED. REMOVED, FABRICATED AND REPLACED FITTING IAW DWG 4758514 AND SRM 51-1-20D.