What was found
INSPECTION TYPE: C3, STATION 25 CUSP WEB/INTERCOSTAL IS CRACKED AT LONG 21L. STOP DRILLED CRACK, NDT VERIFIED STOP DRILL TERMINATED CRACK, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0 FIG 1B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C3, STATION 25 CUSP WEB/INTERCOSTAL IS CRACKED AT LONG 21L. STOP DRILLED CRACK, NDT VERIFIED STOP DRILL TERMINATED CRACK, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0 FIG 1B.