INSPECTION TYPE: C2, STATION 1300 FRAME IS CORRODED BEYOND LIMITS ON LOWER FLANGE AT LONG 36. CUT OUT DAMAGED FRAME SECTION, FABRICATED, INSTALLED 2 SPLICES, ANGLES AND REPLACEMENT FRAME SECTION IAW SRM 53-2-0 FIG 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C2, STATION 1300 FRAME IS CORRODED BEYOND LIMITS ON LOWER FLANGE AT LONG 36. CUT OUT DAMAGED FRAME SECTION, FABRICATED, INSTALLED 2 SPLICES, ANGLES AND REPLACEMENT FRAME SECTION IAW SRM 53-2-0 FIG 2.