What was found
INSPECTION TYPE: C1, AIR CONDITIONING ACCESSORY COMPT AT FS 56 ABOVE L24R FRAME IS CRACKED AT PNEUMATIC DUCT STANDOFF ATTACH BRACKET. REMOVED CRACKED FRAME SECTION. RECEIVED NEW -5 AND -17, -19 SPLICES. HEAT TREATED, LOCATED, DRILLED FRAME SECTION AND SPLICES. ALODINED AND PRIMED, INSTALLED FRAME SECTION AND SPLICES; ALL IAW DC8 SRM 51-1-20D, 21-1-21, 53-2-0 TR 53-125, 51-1-8, TPS-1003 REV A, AND DAC DWG 5614160.