What was found
INSPECTION TYPE: C1, FWD UPPER LT W/W AT STA 857-000 UPPER SPAR CAP AND PLATING HAVE CORROSION BULGING AREA LBL 46. REMOVED CORROSION; (ORIG .270, REM .141) OUT OF LIMITS. FABRICATED REPAIR FILLER, DOUBLER, TRIPLER, PRESSURE PANEL ASSEMBLY DOUBLER, SHIMS, PANEL (P/N 5646674-25), FLOOR SUPPORT ANGLE SPLICE; ALODINED & PRIMED; INSTALLED REPAIR PARTS; ALL IAW DC8 SRM 51-1-8, 57-2-0, AND TIMCO REO G09719.