What was found
INSPECTION TYPE:C1 AFT CARGO PIT AT FS 1200 BETWEEN L33R-34R Z-FITTING IS CORRODED. REMOVED CORROSION IAW DC8 SRM 51-1-8, OUT OF LIMITS IAW DC8 SRM 53-2-0; REMOVED DAMAGED FITTING, REC'D, LOCATED, AND DRILLED UP FITTING AND REPAIR ANGLES IAW DC8 SRM 51-1-24. ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED FITTING AND REPAIR ANGLES IAW DC8 SRM 53-2-0 FIG 2G.