What was found
INSPECTION TYPE:C1 AFT CARGO PIT AT FS 1230 AT L33R Z-FITTING IS CORRODED. REMOVED CORROSION IAW DC8 SRM 51-1-8, OUT OF LIMITS IAW DC8 SRM 53-2-0. REMOVED DAMAGED FITTING IAW DC8 SRM 51-1-20D, REC'D, LOCATED AND DRILLED UP FITTING IAW DC8 SRM 53-2-0 FIG 2G, AND 51-1-24. ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED FITTING AND REPAIR ANGLES IAW DC8 SRM 53-2-0 FIG 2G.