What was found
INSPECTION TYPE:C3 STATION 25 AT LONG 21L ANGLE IN FWD ENTRY DOOR FWD JAMB IS CRACKED. REMOVED, CRACKED INTERCOSTAL, FABRICATED AND INSTALLED INTERCOSTAL IAW DWG 5597646 AND SRM 51-1-20D, 51-1-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C3 STATION 25 AT LONG 21L ANGLE IN FWD ENTRY DOOR FWD JAMB IS CRACKED. REMOVED, CRACKED INTERCOSTAL, FABRICATED AND INSTALLED INTERCOSTAL IAW DWG 5597646 AND SRM 51-1-20D, 51-1-21.