What was found
INSPECTION TYPE: C1, AFT OF STATION 1766 J-FRAME TO LONG. 13L SHEAR TIE IS CRACKED REMOVED, FABRICATED AND REPLACED SHEAR TIE IAW DWG.5773844 AND SRM. 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C1, AFT OF STATION 1766 J-FRAME TO LONG. 13L SHEAR TIE IS CRACKED REMOVED, FABRICATED AND REPLACED SHEAR TIE IAW DWG.5773844 AND SRM. 51-1-20D.