What was found
INSPECTION TYPE: C1 AFT SIDE STATION 1766 J-FRAME TO LONGERON LONG 19R SHEAR TIE IS CRACKED. REMOVED, FABRICATED AND REPLACED SHEAR TIE IAW DWG 5773844 AND SRM 51-3-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C1 AFT SIDE STATION 1766 J-FRAME TO LONGERON LONG 19R SHEAR TIE IS CRACKED. REMOVED, FABRICATED AND REPLACED SHEAR TIE IAW DWG 5773844 AND SRM 51-3-0.