What was found
INSPECTION TYPE: C1 STATION 1120 FRAME CAP IS CORRODED BEYOND LIMITS AT LONG 36. REMOVED AND REPLACED FRAME CAP IAW DWG 5764343 AND REPAIRED FRAME IAW DWG DC8-53A-010, EO DC8-5310-11728-A, SRM 51-1-20D, 51-1-21
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C1 STATION 1120 FRAME CAP IS CORRODED BEYOND LIMITS AT LONG 36. REMOVED AND REPLACED FRAME CAP IAW DWG 5764343 AND REPAIRED FRAME IAW DWG DC8-53A-010, EO DC8-5310-11728-A, SRM 51-1-20D, 51-1-21