What was found
INSPECTION TYPE:C-2 ALC, CORROSION AROUND FASTENERS, HOLE ON CABIN, FLOORBOARD PANEL FS 1040 RBL 45. REMOVED CORROSION FOUND OUT OF LIMITS. REMOVED FLOORBOARD FROM 840 TO 1060 RT RBL 45, CUT SEAT TRACK FROM 870-1050 IAW EO DC853205167C, MAT ID SEAT TRACK AND 1 SPLICE FITTING P/N DC8-003-501 PO SPO94445 SEAT TRACK P/N 2772660 PO -O-. LOCATED, DRILLED, DEBURR & 2 SPLICES. ALODINED & PRIMED. INSTALLED SEAT TRACK. INSTALLED FLOORBOARD FROM 840-1060.