What was found
INSPECTION TYPE:C2 RIGHT UPPER HORIZONTAL STAB LEADING EDGE HAS ELONGATED HOLES BETWEEN XFS 47.5 TO XFS 110.0. REMOVED, FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER AND INTERNAL DOUBLER IAW DWG 5644330 AND SRM 55-2-1 FIG 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 RIGHT UPPER HORIZONTAL STAB LEADING EDGE HAS ELONGATED HOLES BETWEEN XFS 47.5 TO XFS 110.0. REMOVED, FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER AND INTERNAL DOUBLER IAW DWG 5644330 AND SRM 55-2-1 FIG 4.