What was found
INSPECTION TYPE: C-3, FWD PIT FS 600 MIDDLE ROW OF FASTENERS IN SEAT TRACK SPLICE (AS SEEN FROM BELOW) LOCATED AT BC 60 R- CORROSION AROUND FASTENERS & SPACER. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW DC8 SRM 53-2-3. MAT ID FOR SEAT TRACK SPLICES A & B 7075-T6 .160 PO 333834.1 IAW DC8 SRM 53-2-3. FABBED CENTER SEAT TRACK SPLICES A & B, OB & I/B C, D & E SPLICES IAW DC8 SRM 51-1-8, INSTALLED CENTER SEAT TRACK & SPLICES A & B, I/B & O/B & C, D & E. INSTALLED FLOOR PANEL STA 580-608 RBL 60, AIR GRILL STA 513-702.