What was found
INSPECTION TYPE: C-3, MAIN CARGO AREA STA 25 RT SIDE CUSP MEMBRANE HAS CORROSION. REMOVED 2 FITTINGS FROM FS 25, REMOVED FLOOR SUPPORT ANGLES, REMOVED WEB, REMOVED CUSP ANGLES. FABBED CUSP ANGLES IAW DAC DWG 5615180. ALODINED & PRIMED. INSTALLED SUPPORT ANGLE, 2 ANGLE, FLOOR SUPPORT ANGLE, WEB IAW DC8 SRM 51-1-21, 51-20D, 51-3-0, 51-3-1. TWO FITTING FS 25 REMOVED FOM REPLACED ON UPS NR 712495 141495.