What was found
INSPECTION TYPE: C2, STATION 70 LONGERON 35R AND END FITTING ARE CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND REPLACED LONGERON SECTION BETWEEN STATION 70 AND 90, INSTALLED SPLICE AND REPLACED END FITTING IAW SRM 53-2-2 FIG 10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C2, STATION 70 LONGERON 35R AND END FITTING ARE CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND REPLACED LONGERON SECTION BETWEEN STATION 70 AND 90, INSTALLED SPLICE AND REPLACED END FITTING IAW SRM 53-2-2 FIG 10.