What was found
INSPECTION TYPE: C, HORIZONTAL STABILIZER RIGHT NR 36 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, SIDEWALL & BEARING SURFACE. CORROSION REMOVED AT HOLE BOTTOM SURFACE PER SRM 51-21-01 VOL 2 REV 34, MATERIAL REMOVED 0.124 INCH. BARREL NUT HOLE REPAIR PER EN1031-04. BUSHING FABRICATED AND INSTALLED PER EO MD11-5510-19409D.