What was found
INSPECTION TYPE: C, HORIZONTAL STABILIZER RT NR 04 BARREL NUT HOLE FOUND CORROSION ON BOTTOM , SIDEWALL AND BEARING SURFACE. CORROSION AT BOTTOM OF HOLE NR 04 RT REMOVED PER SRM 51-21-01 VOL II REV 3 4, MATERIAL REMOVED 0.046 INCHES IS WITHIN LIMIT PER EO MD11-5510-19409D. REWORKED HOLE PER EN1051-04. BUSHING FABRICATED PER EO MD11-551 0-19409D. (REF. UPS ENGINEERING FILE NR MD11-55-20016)