What was found
INSPECTION TYPE: C, HORIZONTAL STABILIZER RT NR 31 BARREL NUT HOLE FOUND CORROSION ON BOTTOM , SIDEWALL AND BEARING SURFACE. CORROSION AT BOTTOM REMOVED PER SRM51-21-01 VOL II REV 34, MATERIAL REMO VED 0.022 INCHES IS WITHIN LIMITS PER EO MD11-5510-19409D. BARREL NUT HOLE REPAIRED PER EN1050-04. BUSHING FABRICATED AND INSTALLED PER EO MD11-5510-19409-D. (REF. UPS ENGINEERING FILE NR MD11-55-20018)