What was found
INSPECTION TYPE: C, HORIZONTAL STAB LT NR 13 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, SIDEWALL AND BEARING SURFACE. CORROSION AT BOTTOM OF HOLE NR 13 LT REMOVED PER SRM51-21-01 VOL II REV 34, MATERIAL REMOVED 0.051 INCHES IS WITHIN LIMIT PER EO MD11-5510-19409D. BARREL NUT HOLE REPAIRED PER EN1062-04. BUSHING FABRICATED AND INSTALLED PER EO MD11-5510-19409D. (REF. UPS ENGINEERING FILE NR MD11-55-20014)