What was found
INSPECTION TYPE: C, HORIZONTAL STAB LT NR 15 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, SIDEWALL AND BEARING SURFACE. BOTTOM CORROSION AT HOLE NR 15 LT REMOVED PER SRM51-21-01 VOL II REV 34, M MATERIAL REMOVED 0.045 INCH IS WITHIN LIMIT PER EO MD11-5510-19409D. BARREL NUT HOLE REPAIRED PER EN1102-04. BUSHING FABRICATED & INSTALLED PER EO MD11-5510-19409D. (REF. UPS ENGINEERING FILE NR MD11-55-20015).