What was found
INSPECTION TYPE: C, HORIZONTAL STABILIZER LT NR 31 BARREL NUT HOLE FOUND CORROSION ON BOTTOM , SIDEWALL AND BEARING SURFACE. MINOR SURFACE CORROSION ON BOTTOM OF HOLE NR 31 REMOVED PER SRM 51-21-01 VO L II REV 34, MATERIAL REMOVED 0.008 WITHIN LIMITS OF EN1042-04. BARREL NUT HOLE REPAIRED PER EN1042-04. BUSHING FABRICATED AND INSTALLED PER EO MD11-5510-19409D. (REF. UPS ENGINEERING FILE NR MD11-55-20017)