What was found
INSPECTION TYPE: C HORIZONTAL STABILIZER RT NR 07 BARREL NUT HOLE FOUND CORROSION ON BOTTOM , SIDEWALL AND BEARING SURFACE. CORROSION AT BOTTOM OF HOLE NR 07 RT REMOVED PER SRM 51-21-01 VOL II REV 3 4, MATERIAL REMOVED 0.115 IS WITHIN LIMIT PER EN1052-04. 2. BARREL NUT HOLE REPAIRED PER EN1052-04. BUSHING FABRICATED AND INSTALLED P ER EO MD11-5510-19409D. (REF. UPS ENGINEERING FILE NR MD11-55-20016)