What was found
INSPECTION TYPE: C, HORIZONTAL STAB LT NR 35 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, SIDEWALL AND BEARING SURFACE. CORROSION AT BOTTOM LT NR 35 HOLE REMOVED AS PER SRM51-21-01 VOL II REV 3 4, MATERIAL REMOVED 0.054 WITHIN LIMITS OF EN1041-04. BARREL NUT HOLE REPAIRED PER EN1041-04. BUSHING FABRICATED AND INSTALLED PER EO MD11-5510-19409D. (REF. UPS ENGINEERING FILE NR MD11-55-20017)