As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE: C, HORIZONTAL STAB LT NR 06 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, SIDEWALL AN D BEARING SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 MATERIAL REMOVED 0.013 INCH. BARREL NUT HOLE REPAIR PER EN 1138-04. BUSHING FABRICATED & INSTALLED PER EO MD11-5510-19409-D (REF UPS ENGINEERING FILE NR MD11-55-200 14).