What was found
INSPECTION TYPE: C, HORIZONTAL STAB, LEFT BARREL NUT HOLE NR 26 FOUND CORROSION AT BOTTOM, SIDEWALL AND BEARING SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 MATERIAL REMOVED 0.006 INCH. SPLICE FITTING FABRICATED PER EN 1100-04. NEW SPLICE FITTING INSTALLED PER SRM 51-22-01 & SRM 51-38-01 VOL 2 REV 34. BARREL NUT HOLE REPAIRED PER EN 1160-4 (REF UPS ENGINEERING FILE NR MD11-55-20042).