What was found
INSPECTION TYPE: C, HORIZONTAL STAB, RT BARREL NUT HOLE NR 26 FOUND CORROSION AT BOTTOM, SIDEWALL AND BEARING SURFACE. MINOR CORROSION AT BOTTOM OF HOLE REMOVED PER SRM 51-21-01 VOL 2 REV 34 MAT'L REMOVED 0.006 INCH FOUND WITHIN LIMIT PER EO MD11-5510-19409E. SLEEVE BUSHING FABRICATED PER EO MD11-5510-19409E. BARREL NUT HOLE REPAIR CARRIED OUT PER EN1095-04 (REFER UPS ENGINEERING FILE NR MD11-55-20040).