What was found
INSPECTION TYPE: C, HORIZONTAL STAB, RT BARREL NUT HOLE NR 03 FOUND CORROSION AT BOTTOM, SIDEWALL AND BEARING SURFACE. MINOR SURFACE CORROSION AT BOTTOM OF HOLE REMOVED PER SRM 51-21-01 VOL 2 REV 34, MAT'L REMOVED 0.005 INCH FOUND WITHIN LIMITS PER EO MD11-551 0-19409-4. SLEEVE BUSHING FABRICATED PER EO MD11-5510-19409E. BARREL NUT HOLE REPAIR CARRIED OUT PER EN1121-04 (REFER UPS ENGINEERING FILE NR MD11-55-20026).