What was found
INSPECTION TYPE: C, HORIZONTAL STAB, BARREL NUT HOLE NR 30 FOUND CORROSION AT BOTTOM, SIDEWALL AND BEARING SURFACE. CORR REMOVED PER SRM 51-21-01 VOL 2 REV 34 MATERIAL REMOVED 0.041 INCH. SLEEVE BUSHING FABRICATED & INSTALLED PER EO MD11-5510-19409-E. BARREL NUT HOLE REPAIR PER EN 1157-04 (REF UPS ENGINEERING FILE NR MD11-55-20040).