What was found
INSPECTION TYPE: C, HORIZONTAL STAB, BARREL NUT HOLE NR 27 FOUND CORROSION AT BOTTOM, SIDEWALL AND BEARING SURFACE. CORR REMOVED PER SRM 51-21-01 VOL 2 REV 34 MATERIAL REMOVED 0.050 INCH. SLEEVE BUSHING FABRICATED & INSTALLED PER EO MD11-5510-19409-E. BARREL NUT HOLE REPAIRED EN 1157-04 (REF UPS ENGINEERING FILE NR MD 11-55-20040).