What was found
INSPECTION TYPE: C, HORIZONTAL STAB, BARREL NUT HOLE NR 08 FOUND CORROSION AT BOTTOM, SIDEWALL AND BEARING SURFACE. CORROSION AT BOTTOM OF BARREL NUT HOLE REMOVED BOTTOM BORED DOWN 0.018 INCH PER EN 1124-04. SLEEVE BUSHING FABRICATED & INSTALLED PER EO MD11-55 10-19409-E. BARREL NUT HOLE REPAIRED PER EN 1158-04 (REF UPS ENGINEERING FILE NR MD11-55-20025).