What was found
INSPECTION TYPE: C, HORIZONTAL STAB NR 36 BARREL NUT HOLE FOUND CORROSION ON BOTTOM BEARING & SIDE WALL SURFACE. CORROSION AT BEARING & S/W REAMED TO 2.602 PER EN1179-04. BLEND OUT 0.090 INCH DEEP FOUND OUT OF LIMIT. REWORKED B/N HOLE NR 36 RT. FAB & REPAIR SLEEVE BUSHING PER EO MD11-5510-19409-G & EN1179-04, APPLIED SEALANT PR1422B2 AT B/N HOLE NR 36 RT. FAB REPAIR DOUBLER & FILLER USING 7075-T6-0.063 & 0.050 INCH. RT B/N HOLE NR 36, REPAIRED WITHIN LIMIT, SATISFACTORY.