What was found
INSPECTION TYPE: C, LT HORIZ STAB BARREL NUT HOLE NR 28 FOUND CORRODED. CORROSION AT B/N HOLE NR 28 LT REMOVED AND REAMED TO 1.178 INCHES AND BLEND TO 0. 06 INCH IAW EO MD11-5510-19409-G FOUND EXCEEDED LIMIT. REPAIR AND FAB SLEEVE BUSHING IAW EO MD11-5510-19409-G. APPLIED PR1422B2 SEALANT AT B/N HOLE NR 28 LT IAW EN 1233-04. REPAIR AND INSTALLED SLEEVE BUSHING IAW EO MD11-51 0-19409-G AND EN.1233-04 FOUND WITHIN LIMIT,SATIS.