What was found
INSPECTION TYPE: C, LT HORIZ STAB BARREL NUT HOLE NR 09 FOUND CORRODED. CORROSION AT B/N HOLE NR 09 LT REMOVED AND REAMED TO 0.988 INCH AND BLEND TO 0.0 40 INCH DEEP IAW EO MD11-5510-19409-G FOUND EXCEEDED LIMIT. REPAIR AND FAB SL EEV BUSHING IAW EO MD11-5510-19409-G. APPLIED SEALANT PR1422B2 AT B/N H OLE NR 09 LT IAW EN.1229-04. REPAIR AND INSTALLED SLEEVE BUSHING AT B/N HOL E NR 09 LT IAW EO MD11-5510-19409-G AND EN. 1229-04 FOUND WITIN LIMIT,SATIS