What was found
INSPECTION TYPE: C, LT HORIZ STAB BARREL NUT HOLE NR 34 FOUND CORRODED ON BOTTOM AND SIDEWALL SURFACE. CORROSION AT B/N HOLE NR 34 LT REMOVED AND REAMED TO 1.178 INCH BLEND TO 0.020 INCH DEEP FOUND EXCEED LIMIT IAW EO MD11-5510-19409-G. FAB AND REPAIR SLEEVE BUSHING IAW EO MD11-5510-19409-G. APPLIED SEALANT PR1422B2 AT B/N HOLE NR 34 LT IAW EN.1228-04. REPAIR AND INSTALLED SLEEVE BUSHING IAW EO MD11-55 10-19409-G AND EN1228-04 FOUND WITHIN LIMIT AND SATIS.